Citizen CL-S703 Label Maker User Manual


 
Chapter 2 Operating Principles
2-3. Operation Panel
2-47 CL-S700/CL-S703/CL-S700R
Submenu Name
[Factory Mode Settings
Menu name]
Adjustable Value
(Default Value)
Description
Fix-Thru Level
[Fix Through Cal Level]
0.01 to 3.30V
(2.30 V)
Performs sensitivity adjustment of the front fixed
sensor for Media Sensor menu “See Through”.
The amount of light received is set to “2.30V”.
Fix-Refl Level
[Fix Reflect Cal Level]
0.01 to 3.30V
(2.10 V)
Performs sensitivity adjustment of the front fixed
sensor for Media Sensor menu “Reflect”. The
amount of light received is set to “2.10V”.
Fix-None Level
[Fix SensNone Cal Level]
0.01 to 3.30V
(2.05 V)
Performs sensitivity adjustment of the front fixed
sensor for Media Sensor menu “None”. The
amount of light received is set to “2.05V”.
Adj-Thru Level
[Adj Through Cal Level]
0.01 to 3.30V
(2.30V)
Performs sensitivity adjustment of the adjustable
sensor for Media Sensor menu “See Through”.
The amount of light received is set to “2.30V”.
Adj-Refl Level
[Adj Reflect Cal Level]
0.01 to 3.30V
(2.10 V)
Performs sensitivity adjustment of the adjustable
sensor for Media Sensor menu “Reflect”. The
amount of light received is set to “2.10V”.
Adj-None Level
[Adj SensNone Cal Level]
0.01 to 3.30V
(2.05 V)
Performs sensitivity adjustment of the adjustable
sensor for Media Sensor menu “None”. The
amount of light received is set to “2.05V”.
Peel Sens Level
0.01 to 3.30V
(1.50 V)
Sets the threshold value for the peel sensor.
Cont Paper Sens
Through/Reflect
(Reflect)
When continuous media is used, selects the
sensor type to be used for detecting paper end.
Dbl Heat Menu
[Double Heat Menu]
On/Off
(Off)
Sets whether to display the menu of "Double
Heat".
PwrOn Head Chk
[Power On Head Check]
On/Off
(On)
Sets whether to perform head check at power
ON or not.
Head Chk Start
[Head Check Start Pos.]
Dots 001 to 848
(Dot 001)
Designates the start dot for head check.
Head Chk Stop
[Head Check Stop Pos.]
Dots 001 to 848
(Dot 848)
Designates the end dot for head check.
Rbn End Detect
[Ribbon End Detection]
Normal/Slow
(Normal)
Sets the ribbon end detection time.
Parallel ErrOut On/Off
(On)
Select whether to activate the Fault signal of
parallel interface at the time of error occurrence.
USB Serial Num
[USB Serial Number]
On/Off
(Off)
Select whether to send the serial number to the
host when operating the printer through the USB
interface.