Citizen CL-S703 Label Maker User Manual


 
Chapter 3 Disassembly and Maintenance
3-6. Adjustments
CL-S700/CL-S703/CL-S700R 3-50
(2-4) Init Adj-Refl sensitivity adjustment
Init Adj-Refl sensor is the reflective sensor (adjustable type), i.e. “SA, Sensor Bottom”
(Adjustable type).
Preparation:
Open the head block and the sensor arm, and then set label with black mark or tag with
black mark.
When label with black mark is used:
1. Prepare recommended media or media to be used.
2. Peel off labels from the liner.
3. Set the media and be sure that the media is put on the “SA, Sensor Bottom”
(Adjustable type) (avoid the black mark area).
4. Close the sensor arm and the head block.
When tag with black mark is used:
1. Prepare recommended media or media to be used.
2. Set the media (if continuous tag is used, set it) and be sure that the media is put on the
“SA, Sensor Bottom” (Adjustable type) (avoid the black mark area).
3. Close the sensor arm and the head block.
Procedure:
1. Enter Factory/Service mode by turning on the power while pressing and holding the
[MENU], [FEED] and [STOP] keys.
“Factory Setup” main menu appears.
2. In “Factory Setup” main menu, press the [STOP] (X) key to enter Factory Setup mode.
The first submenu “Sens Vol Adj.” appears.
3. Press the [MENU] (T) key until “Init Adj-Refl” submenu appears.
4. Press the [STOP] (X) key to enter Init Adj-Refl sensitivity adjustment mode.
5. Press the [MENU] (T) key to select “Exec”.
W
X
Init Adj-Refl
No
Exit
Enter
S
T
W
X
Init Adj-Refl
Exec
Exit
Enter
S
T
W
X
Factory Setup
Init Adj-Refl
Exit
Enter
S
T