Citizen CL-S703 Label Maker User Manual


 
Chapter 2 Operating Principles
2-3. Operation Panel
2-45 CL-S700/CL-S703/CL-S700R
(3) How to change the settings in Factory mode
- In Factory mode, DO NOT change the factory-set values unless you need to change
them, since there are essential items related to printing accuracy, etc.
- Do not turn OFF the power of the printer until you finish the adjustment. If it is
turned OFF, you need to repeat the adjustment from the beginning.
- The value adjusted here is retained until you change it with the same
procedure. Even if you perform initialization by selecting “Test Mode” main
menu, “Factory Default” submenu and “Yes”, the changed value is not
returned to the initial value set at the factory.
(3-1) Submenu table in Factory mode
The following table shows the submenus of “Factory Setup” main menu.
*1 “[Factory Mode Settings Menu name]” in “Submenu Name” column shows the name
that will be printed in “Factory Mode Settings”. (Refer to “(2) How to print the Factory
Mode Settings menus”.)
*2 “+” shows that the object electrically moves forward/rightward. “-“ shows that the object
electrically moves backward/leftward. 8 dots correspond to 1 mm (203 dots correspond
to 1”).
Submenu Name
[Factory Mode Settings
Menu name]
Adjustable Value
(Default Value)
Description
Sens Vol Adj
Displays the level of each media sensor.
Init Fix-Thru
Performs calibration of the transparent sensor
sensitivity (fixed type). For details, refer to “3-6-1
(2) Sensor sensitivity adjustment (Factory
mode)” in Chapter 3.
Init Fix-Refl
Performs calibration of the reflective sensor
sensitivity (fixed type). For details, refer to “3-6-1
(2) Sensor sensitivity adjustment (Factory mode
in Chapter 3.
Init Adj-Thru
Performs calibration of the transparent sensor
sensitivity (adjustable type). For details, refer to
3-6-1 (2) Sensor sensitivity adjustment (Factory
mode” in Chapter 3.
Init Adj-Refl
Performs calibration of the reflective sensor
sensitivity (adjustable type). For details, refer to
3-6-1 (2) Sensor sensitivity adjustment (Factory
mode” in Chapter 3.
Caution