Digi MIL-3000FTX Printer User Manual


 
MIL-3000FTX Series of FastPort Print Servers A-3
A.5 Connectors
A.5.1 Serial Port Connector
A.5.2 RJ-45 Connector
Pin 1: Transmit data + Pin 3: Receive data +
Pin 2: Transmit data - Pin 6: Receive data -
A.5.3 Parallel Port Connector
A.6 Environmental Operating Conditions
A.7 System LEDs
PIN Number Signal PIN Number Signal
1NC6 NC
2 RXD 7 RTS/DTR
3 TXD 8 CTS
4 DTR/RTS 9 NC
5 GND
PIN Number Signal PIN Number Signal PIN Number Signal
1 PASTB 10 ACK 19 GND
2 PAD0 11 BUSY 20 GND
3 PAD1 12 PE 21 GND
4 PAD2 13 ONLINE 22 GND
5 PAD3 14 AUTO FEED 23 GND
6 PAD4 15 FAULT 24 GND
7 PAD5 16 INIT 25 GND
8 PAD6 17 SLCTIN
9 PAD7 18 GND
Parameters Minimum Maximum
Operating Temperature +5° C 40° C
Humidity: Non-condensing 10% 95%
Altitude test NA 40,000 ft. (at 40° C)
Temperature test (Operating) 5° C 50° C
Temperature test (Packaged) -25° C 70° C
LED Functioned Color
RX Transmitting on the network Green
TX Receiving from the network Green
SYS System is active Green
SER Serial port activity Green
PWR System power is On Green
LNK Link is active Yellow
NET Network activity Yellow
P1 Parallel data activity on parallel port 1 Yellow
P2 (MIL-3200FTX & MIL-3310FTX only) Parallel data activity on parallel port 2 Yellow
P3 (MIL-3310FTX only) Parallel data activity on parallel port 3 Yellow