MIL-3000FTX Series of FastPort Print Servers C-10
C.5.9 Autosensing printer has trouble printing
• Check the job time-out value and increase it 45 to 60 seconds.
• Turn off banner option.
• Use ACT to select the send a Control+D queue option (see NetWare
Configuration). This resets the printer after a PostScript job.
C.5.10MS Windows jobs print with an extra page
Use Print Manager or the Windows Printer Setup screen to turn off
the send a form feed option.
C.5.11File server displays an Incomplete Packet error message
By default, FastPort finds NetWare servers using repeated broadcasts of
different frame types. If a server is bound to a specific frame type, the
server issues error messages for frames it does not understand. Use the
Advanced Configuration menu in ACT to set a specific frame type.
C.6 Notification not Working if Created by PCONSOLE
Verify that the printer type is Defined Elsewhere and not any other
type. Select the Print Servers menu and change the settings in the
Printers submenu.
C.7 FastPort Console Messages
This section lists and describes FastPort console messages.
C.8 Could not attach QUEUE1
Verify that the queue name is spelled correctly and whether another print
server is servicing QUEUE1.
C.8.1 Attaching queue QUEUE1 on server SERVER1
FastPort has read the configuration file and has attached to the queue that
asked to be serviced.
C.8.2 Read Configuration File
FastPort has found and read the configuration file. It then displays it as
verified.