4. Exit the Serial Port Selection and Configuration mode: Press and release an
output button.
C O N T R O L
PRESET
ENTER
ESCVIEW
5
31 32
0
All Control buttons and the Output 31 (71) and Output 32 (72)
buttons return to unlit or background illumination.
Press and release
an output button.
Reset Operations
The rear panel has a Reset button that initiates four levels of resets (numbered 1, 3, 4, and 5
for the sake of comparison with an Extron IPL product). The Reset button is recessed, so
use a small screwdriver, a pointed stylus, or a ballpoint pen.
For different reset levels, press and hold the button while the switcher is running or press
and hold the button while you apply power to the switcher.
See the table on the next page for a summary of the modes.
ATTENTION: Review the reset modes carefully. Using the wrong reset mode may
result in unintended loss of flash memory programming, port reassignment, or a
controller reboot.
NOTE: The reset modes listed on the next page close all open IP and Telnet
connections and close all sockets. Also, the following modes are separate functions,
not a continuation from Mode 1 to Mode 5.