Extron electronic 7200 Switch User Manual


 
Physical Switcher Layout Calls the FOX Matrix Physical Configuration window
(see figure 45), which displays the I/O board type installed in each slot. The
Channels
field can be helpful in identifying a specific input or output. In figure 45, for example,
input 29 is identified as slot 4, input transceiver E (4o05).
Figure 45. Physical Configuration Window
Name Presets Allows you to name each of the 32 (FOX Matrix 3200) or
64 (FOX Matrix 7200) memory presets.
NOTE: Preset names are limited to 12 upper‑ and lower‑case alphanumeric
characters, space, and the _ and / characters. The HTML language reserves
certain characters for specific functions (see Special Characters on page 70).
Show RS-232 Strings Displays the ASCII commands that are used by the current
configuration. You can refer to these for SIS programming.
I/O Group settings Displays the inputs/outputs groups window, which allows
you to assign inputs and outputs to any one of four groups (or no group).
Room configuration Allows you to assign outputs to rooms or delete outputs
from rooms.
NOTE: A room is a subset of outputs that are logically related to each other, as
determined by the operator. The FOX matrix switcher supports up to 10 rooms,
each of which can consist of 1 to 16 outputs.
Initialize Initializes and clears any or all of the following: ties, presets, preset
names, icon names, and icons.
FOX Matrix 3200 and 7200 Switchers • Matrix Software 87