Extron electronic 7200 Switch User Manual


 
Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
IP setup commands (continued)
Set e-mail events for recipient
EX5#X5!
,
X5$
,
X5%
,0EM
}
Ipe
X5#X5!
*
X5$
*
X5%
*0
]
You must first have set an e-mail
recipient for the
X5!
variable, using the
separate Set e-mail recipient (CR)
command on the previous page.
Example:
E
I69,63,3,0EM
}
IpeI69*63*3*0
]
E-mail account #69 (recipient #5,
JSmith), will receive fail/missing and
fixed/restored messages for input 63.
Read e-mail notifications for one
account (recipient)
EX5#X5!
,
X5$
,0EM
X5%X5%X5%
...
X5%]
Set DHCP on or off
EX5^
DH
}
Idh
X5^] X5^
: 0 = off, 1 = on
Read DHCP on or off status
E
DH
} X5^]
Set serial port parameters
EX5&
*
X5*
,
X5(
,
X6)
,
X6!
CP
}
Cpn
X5&
Ccp
X5*
,
X5(
,
X6)
,
X6!]
Read serial port parameters
EX5&
CP
} X5*
,
X5(
,
X6)
,
X6!]
Set serial port mode
EX5&
*
X6@
CY
}
Cpn
X5&
Cty
X6@] X6@
: 0 = RS-232, 1 = RS-422
Read serial port mode
EX5&
CY
} X6@]
Set verbose mode
EX6#
CV
}
Vrb
X6#]
Read verbose mode
E
CV
} X6#]
Configure current port timeout
E
0*
X6$
TC
}
Pti0*
X6$]
Read current port timeout
E
0TC
} X6*]
Configure global IP port timeout
E
1*
X6$
TC
}
Pti1*
X6$]
Read global IP port timeout
E
1TC
} X6*]
SNMP setup commands
NOTE: See SNMP Settings Page, on page 103. This HTML page provides introductory information about Simple Network
Management Protocol (SNMP) and is the preferred method for performing the functions listed below.
Port mapping
Map SNMP port
E
A
X6%
PMAP
}
PmapA
X6%]
Assign a specific port. Default:161.
Reset SNMP port to default
E
A161PMAP
}
PmapA00161
]
Disable SNMP port
E
A0PMAP
}
PmapA00000
]
Assign no port for SNMP.
Assign a valid port to enable.
View current SNMP port
E
APMAP
} X6%]
Unit contact name and location
NOTE: No contact or location (as opposed to NotSpecified, the default value) is not a valid entry.
Set unit contact info
E
C
X6^
SNMP
}
SnmpC*
X6^]
Set contact info to
X6^
.
Reset unit contact info to default
E
CSNMP
}
SnmpC*NotSpecified
]
View unit contact info
E
CSNMP
} X6^]
Set unit location info
E
L
X6^
SNMP
}
SnmpL*
X6^]
Set location info to
X6^
.
Reset unit location info to default
E
LSNMP
}
SnmpL*NotSpecified
]
View unit location info
E
LSNMP
} X6^]
Community names
Set unit read-only community name
E
P
X6&
SNMP
}
SnmpP*
X6&]
Set read-only (public) name to
X6&
.
Reset read-only community name
to default
E
PSNMP
}
SnmpP*public
]
View unit read-only name
E
PSNMP
} X6&]
Set unit read-write community
name
E
X
X6&
SNMP
}
SnmpX*
X6&]
Set read-write (private) name to
X6&
.
Reset read-write community name
to default
E
XSNMP
}
SnmpX*private
]
View unit read-write name
E
XSNMP
} X6&]
Command and Response Table for IP- and SNMP-Specific SIS Commands (continued)
FOX Matrix 3200 and 7200 Switchers • Programming Guide 69