Fujitsu V01 Network Hardware User Manual


 
Chapter 4 Troubleshooting
IP-900 Series
116
Code Name Description Details (The part after the * mark is not displayed.)
E013 Temperature warning (*2) Thermal alarm (alarm only) detected #1 TEMP1=t1 TEMP2=t2 FAN=xxxRPS
#2 TEMP1=t1 TEMP2=t2 FAN=xxxRPS
* Details are as follows:
#1/#2: Number of the temperature sensor that has
detected a thermal alarm
t1: Temperature indicated by temperature sensor 1
t2: Temperature indicated by temperature sensor 2
xxx: FAN rotational speed
*E013 Thermal alarm recovery (*2) Recovered from thermal alarm #1 TEMP1=t1 TEMP2=t2 FAN=xxxRPS
#2 TEMP1=t1 TEMP2=t2 FAN=xxxRPS
* Details are as follows:
#1/#2 : Number of the temperature sensor that has
detected a thermal alarm recovery
t1: Temperature indicated by temperature sensor 1
t2: Temperature indicated by temperature sensor 2
xxx: FAN rotational speed
E082 CODEC1 error (*4) Main HD CODEC LSI error detected
*E082 CODEC1 error recovery (*4) Recovered from main CODEC LSI error
E083 CODEC2 error (*4) Sub CODEC LSI error detected
*E083 CODEC2 error recovery (*4) Recovered from sub CODEC LSI error
E084 CF card access error (*3) CF card access failure detected
E085 CF card power error (*3) Overcurrent to CF card detected
E08B SUB CPU1 error (*4) SUB CPU1 error detected
*E08B SUB CPU1 error recovery (*4) Recovered from SUB CPU1 error
E08C SUB CPU2 error (*4) SUB CPU2 error detected
*E08C SUB CPU2 error recovery (*4) Recovered from SUB CPU2 error
E08E Clock error (*1) Clock error or interruption detected #1 to #4 * Indicates the location where a clock error
has occurred.
E08F Memory error (*1) SDRAM memory check error detected #1 to #7 * Indicates the location where a memory error
has occurred.
E093 Sending buffer overflow (*7) Sending buffer overflow occurred #1, #2 * Indicates the location where a sending buffer
overflow has occurred.