Fujitsu V01 Network Hardware User Manual


 
Chapter 3 Web Operation
IP-900 Series
87
The device does not send the encoder address report when the following condition applies: [IP version]
of Output interface settings (Main encoder ethernet) described in Section 3.3.1, "Setting (Encoder)," and
[IP version] of Main encoder destination settings described in Section 3.3.2, "Encoder Address Report,"
do not match. (The same thing can be said regarding the sub encoder.)
The device does not send the encoder address report when the following condition applies: "Unicast
(simplex)" is selected for [Streaming mode] of Output interface settings (Main encoder ethernet)
described in Section 3.3.1, "Setting (Encoder)," and [Streaming destination IP address] of Output
interface settings (Main encoder ethernet) described in Section 3.3.1, "Setting (Encoder)," and [IP
address] of Main encoder destination settings described in Section 3.3.2, "Encoder Address Report," do
not match. (The same thing can be said regarding the sub encoder.)