Chapter 3 Web Operation
IP-900 Series
33
Item Description Parameter
Password for
PPPoE
Specify the password when
"PPPoE" is set for [IP address
mode].
64 en-size alphanumeric characters
(Default: Blank)
IPv6 network
settings
IP address mode Specify the IPv6 address
acquisition method.
- Stateless
- Static IP (default)
IP address
Specify the IPv6 address when
"Static IP" is set for [IP address
mode].
Global unicast IP address
2xxx:xxxx:…:xxxx to 3xxx:xxxx:…:xxxx
(Default: ::)
Prefix Specify the prefix of the IPv6
address when "Static IP" is set
for [IP address mode].
3 to 128
(Default: 64)
Default gateway
address
Specify the default gateway
address when "Static IP" is set
for [IP address mode].
Global unicast address
2xxx:xxxx:...:xxxx to
3xxx:xxxx:...:xxxx
(Default: ::)
Other settings
User
authentication
Specify whether to enable user
authentication for accessing the
Web screen.
- Enable
- Disable (Default)
User ID Specify the user name for
authentication.
16 en-size alphanumeric characters
(Default: Blank)
Password Specify the password for
authentication.
16 en-size alphanumeric characters
(Default: Blank)
WEB server title Specify the character string to
be displayed on the title bar of
the Web screen. It will be used
to identify the Web screen with
the equipment name.
The specified string must be not exceed 64
bytes (assuming one double-space character
as 2 bytes and one single-space character as 1
byte). (Default: blank)
* Single-space kana characters are handled as
double-space characters.
Note: If power-on is performed in combination with the Cancel key (see IP-900 series User’s Guide),
the IP address and subnet mask on both LAN and CONSOLE ports are temporarily reset to the defaults
(LAN IPv4 address 10.0.0.1, subnet mask 255.0.0.0, IPv6 address :: and prefix: 64). If it becomes
unclear what an IP address is, connect the equipment with the defaults and use the setup menu to
confirm the IP address and subnet mask. In this case, the password restriction is also disabled. Hold
down the MNT button until the RDY LED starts blinking in orange. The equipment reboots, and the IP
address and subnet mask that were set for the equipment are restored.