Chapter 3 Web Operation
IP-900 Series
46
Code Name Description Details (The part after the * mark is not displayed.)
E013 Temperature warning (*2) Thermal alarm (alarm only) detected #1 TEMP1=t1 TEMP2=t2 FAN=xxxRPS
#2 TEMP1=t1 TEMP2=t2 FAN=xxxRPS
* Details are as follows:
#1/#2: Number of the temperature sensor that has
detected a temperature error
t1: Temperature indicated by temperature sensor 1
t2: Temperature indicated by temperature sensor 2
xxx: FAN rotational speed
E082 CODEC1 error (*4) Main CODEC LSI error detected
E083 CODEC2 error (*4) Sub CODEC LSI error detected
E084 CF card access error (*3) CF card access failure detected
E085 CF card power error (*3) Overcurrent to CF card detected
E08B SUB CPU1 error (*4) SUB CPU1 error detected
E08C SUB CPU2 error (*4) SUB CPU2 error detected
E08E Clock error (*1) Clock error or interruption detected #1 to #4 * Indicates the location where a clock error
has occurred.
E08F Memory error (*1) SDRAM memory check error detected #1 to #7 * Indicates the location where a memory
error has occurred.
E093 Sending buffer overflow (*6) Sending buffer overflow occurred #1, #2 * Indicates the location where a sending buffer
overflow has occurred.
If an alarm recovers occurs after an alarm occurrence.
*1: After occurrence of this error, the ALM LED remains on. The device needs to be rebooted to turn off the ALM LED.
*2: The ALM LED blinks while this alarm is active. The LED goes off when the alarm cause is recovered.
*3: After occurrence of this error, the ALM LED remains to blink.
*4: After occurrence of this error, the operation is retired for recovery. If the retry for recovery is unsuccessful, the ALM LED remains on. The device needs to be
rebooted to turn off the ALM LED.
*5: If an extreme temperature is detected, all LEDs except LINK/ACT, 10/100 go on. The device needs to be rebooted to turn off the LEDs.
*6: The ALM LED blinks while this alarm is active. The LED goes off when the alarm cause is recovered.
In case that the settings exceeds the capacity of the IP network, please reconfigure them to meet the network requirement
*7: The IN DWN LED blinks while this alarm is active. The LED goes off 10 seconds after the error cause is recovered. See 3. 2. 11 Performance Statistics for the
details of the statistical information counter about the alarm occurrence.