GE GFK-1918D Computer Accessories User Manual


 
Motion Programming
Local Logic
GFK-1918D CIMPLICITY Logic Developer - PLC Version 4.00 97
Local Logic Variables
Local Logic is designed to complement a PLC’s logic and mathematical
capabilities. Solving small Local Logic and mathematical sets require a tight
synchronization with the controlled motion.
Logic Developer - PLC includes a table containing Local Logic variables, the Local
Logic Variable Table (LLVT), that you can drag into your logic programs. As
illustrated in the diagram below, the LLVT has several tabs that organize the
variables by category:
To view the LLVT
1. In the InfoViewer tab of the Navigator, expand the Logic Developer - PLC library then expand the
Local Logic Editor book and double-click Local Logic Variable Table.
The LLVT appears in the Infoviewer.
The variables or data in each tab are:
Axis 1 Variables specific to axis 1
Axis 2 Variables specific to axis 2
Axis 3 Variables specific to axis 3
Axis 4 Variables specific to axis 4
Global Global data such as module status code
CTL bits DSM general Control/Status bits
Parameter Registers DSM parameter data
Click a heading to
sort the table in
ascending order.
Click again to sort
descending.
Click a tab to view a
group of variables
Right-click a name
to copy it to the