GE GFK-1918D Computer Accessories User Manual


 
GE Fanuc PLC Targets
Configuring Communication
32 CIMPLICITY Logic Developer - PLC Version 4.00 GFK-1918D
3
To set an IP address for other Series 90™-30 CPUs (not CPU364 or CPU374)
1. In the Project tab of the Navigator, expand the Hardware Configuration node.
2. Right-click the slot containing an Ethernet Interface Module (IC693CMM321)and choose Configure.
The Parameter editor opens showing the configuration settings for the module.
3. In the Settings tab, double-click the IP Address field.
The IP Address dialog box appears.
4. Enter the IP address and click OK.
To download an IP address to a non-PACSystems™ target
1. Configure a CPU or Ethernet COM Module with an IP address using Hardware Configuration.
2. Right-click the target and choose Properties.
The Inspector displays the target’s properties.
3. In the Physical Port property, select a serial connection.
4. Right-click the target and choose Go Online.
5. Right-click the target and choose Download to PLC.
The Download to PLC dialog box appears.
6. Select Hardware Configuration and click OK.
The IP address is assigned to the PLC.
7. Right-click the target anch choose Go Offline.
8. Right-click the target and choose Properties.
9. In the Physical Port property, select Ethernet.
The next time you go online, Machine Edition will use an Ethernet connection with
the specified IP address.