IBM 8682 Server User Manual


 
Diagnostic error codes
Note: In the following error codes, if XXX is 000, 195,or197 do not replace a
FRU. The description for these error codes are:
000 The test passed.
195 The Esc key was pressed to abort the test.
197 This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
Error Code/Symptom FRU/Action
001-XXX-000
(Failed core tests)
1. System Board
001-XXX-001
(Failed core tests)
1. System Board
001-250-000
(Failed System Board ECC)
1. System Board
001-250-001
(Failed System Board ECC)
1. System Board
005-XXX-000
(Failed Video test)
1. Video Adapter (if installed)
2. System Board
011-XXX-000
(Failed COM1 Serial Port test)
1. System Board
011-XXX-001
(Failed COM2 Serial Port test)
1. System Board
014-XXX-000
(Failed Parallel Port test)
1. System Board
015-XXX-001
(Failed USB test)
1. System Board.
015-XXX-015
(Failed USB External Loopback test)
1. Make sure parallel port is not disabled.
2. Re-run USB External Loopback test.
3. System board.
015-XXX-198
(USB device connected during USB test)
1. Remove USB devices from USB1 and USB2.
2. Re-run test.
3. System Board.
020-XXX-000
(Failed PCI Interface test)
1. System Board
020-XXX-001
(Failed Hot-Swap Slot 1 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
Symptom-to-FRU index 103