Error Code/Symptom FRU/Action
201
(Memory test error, see ″Memory Settings″
on page 37) If the server does not have
the latest level of BIOS installed, update
the BIOS to the latest level and run the
diagnostic program again.
1. Run memory diagnostics.
2. DIMM
3. Memory card
4. System Board
229
(Cache error)
1. Processor
2. Optional Processor (if installed)
289
(DIMM has been disabled by user or
system, see ″Memory Settings″ on page
37)
1. Run Configuration/Setup
2. Disabled DIMM
301
(Keyboard or keyboard controller error)
1. Keyboard
2. System Board
303
(Keyboard controller error)
1. System Board
2. Keyboard
602
(Invalid diskette boot record)
1. Diskette
2. Diskette Drive
3. Cable
4. System Board
604
(Diskette drive error)
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
662
(Diskette drive configuration error)
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
962
(Parallel port error)
1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. System Board
11XX
(System board serial port 1 or 2 error)
1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. System Board
1162
(Serial port configuration conflict)
1. Disconnect external cable on serial port
2. Run Configuration/Setup
3. System board
1200
(processor machine check)
1. Processor
112 IBM xSeries 350 Type 8682: Hardware Maintenance Manual