IBM 8682 Server User Manual


 
Error Code/Symptom FRU/Action
020-XXX-002
(Failed Hot-Swap Slot 2 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
020-XXX-003
(Failed Hot-Swap Slot 3 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
020-XXX-004
(Failed Hot-Swap Slot 4 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
020-XXX-005
(Failed Hot-Swap Slot 5 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
020-XXX-006
(Failed Hot-Swap Slot 6 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
030-XXX-000
(Failed Internal SCSI interface test)
1. System Board
030-XXX-00N
(Failed SCSI test on PCI slot N. Check
system error log before replacing a FRU.)
1. Adapter in Slot N
035-XXX-099
1. No adapters were found.
2. If adapter is installed re-check connection.
035-XXX-S99
(Failed RAID test on PCI slot S. S =
number of failing PCI slot. Check System
Error Log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-SNN
(Check System Error Log before
replacing a FRU. S = number of failing
PCI slot; NN = SCSI ID of failing fixed
disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID adapter initialization failure)
1. ServeRAID Adapter in slot S is not configured properly. Obtain the
basic and extended configuration status and refer to the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable
3. SCSI Backplane
4. Adapter
075-XXX-000
(Failed Power Supply test)
1. Power Supply
089-XXX-001
(Failed Microprocessor test)
1. Microprocessor
089-XXX-002
(Failed Optional Microprocessor test)
1. Optional Microprocessor 2
089-XXX-003
(Failed Optional Microprocessor test)
1. Optional Microprocessor 3
104 IBM xSeries 350 Type 8682: Hardware Maintenance Manual