IBM 8682 Server User Manual


 
Temperature related system shutdown
Message Action
System shutoff due to CPU X over temperature
(level-critical; CPU X is over temperature)
1. Ensure system is being properly cooled, see
“Temperature checkout” on page 23
2. Replace CPU X
System shutoff due to CPU X under temperature
(level-critical; CPU X is under temperature)
1. Ambient temperature must be within normal
operating specifications (see “Features and
specifications” on page 3
2.
System shutoff due to DASD temperature (sensor X)
(level-critical; DASD area reported temperature outside
recommended operating range)
1. Ensure system is being properly cooled, see
“Temperature checkout” on page 23
System shutoff due to high ambient temperature
(level-critical; high ambient temperature)
1. Ambient temperature must be within normal
operating specifications (see “Features and
specifications” on page 3
System shutoff due to faults on each supply
(level-critical; each installed power supply encountered a
fault condition)
1. See “Power checkout” on page 20.
DASD checkout
Message Action
Hard drive X removal detected
(level-critical; hard drive X has been removed)
1. Information only, take action as appropriate.
Hard Drive (SCSI ID X) fault
(level-critical; error has occurred on a DASD drive in a
RAID configuration causing it to be defunct)
1. Ambient temperature must be within normal
operating specifications (see “Features and
specifications” on page 3
CPU checkout
Message Action
Host BIST fail
(level-informational; host’s built-in self test failed)
1. Reseat CPU
2. Replace CPU
Internal Error CPU X fault
(level-critical; specified processor reported internal error and
is held offline and system restarted)
1. If problem persists, replace CPU X.
Symptom-to-FRU index 121