IBM 8682 Server User Manual


 
Message Action
Power Supply X Temperature Fault
(level-critical; power supply x had over temperature
condition)
1. Ensure system is being properly cooled; see
“Temperature checkout” on page 23
2. Replace Power Supply X
System over temperature for CPU X
(level-warning; CPU X reporting over temperature
condition)
1. Ensure system is being properly cooled; see
“Temperature checkout” on page 23
2. Replace system board.
System under recommended CPU X temperature
(level-warning; system reporting under temperature
condition for CPU X)
1. Ambient temperature must be within normal
operating specifications; (see “Features and
specifications” on page 3).
System over recommended ambient temperature
(level-warning; ambient temperature too warm for safe
system operation)
1. Ambient temperature must be within normal
operating specifications; (see “Features and
specifications” on page 3).
Fan error messages
Message Action
Fan X fault
(level-critical; fan X beyond recommended RPM
range)
1. Check connections to fan X
2. Replace fan X
Power error messages
Message Action
Power supply X DC good fault
(level-critical; power good signal not detected for power
supply X)
1. Replace power supply X
Power supply X fan fault
(level-critical; fan fault in power supply X)
1. Replace power supply X
Power supply X fault
(level-critical; overcurrent condition exists)
1. See “Power checkout” on page 20
Power supply X 12V fault
(level-critical; overcurrent condition detected)
1. See “Power checkout” on page 20
Power supply X 3.3V fault
(level-critical; 3.3V power supply X had an error)
1. See “Power checkout” on page 20
Power supply X 5V fault
(level-critical; 5V power supply X had an error)
1. See “Power checkout” on page 20
Power supply current exceeded max spec value
(level-critical; current draw in system is over allowance for
a single supply)
1. See “Power checkout” on page 20
Symptom-to-FRU index 119