IBM 8682 Server User Manual


 
TechConnect CD Action
Can’t start TechConnect
®
CD. Be sure you’re starting the CD on a system with Microsoft
®
Windows
®
installed.
Can’t view publications from TechConnect CD,
or text is unreadable.
Be sure you have the Adobe reader installed (available from the
TechConnect CD).
Diskette Factory CD Action
Get “time out” or “Unknown host” errors Be sure you have access to the Internet through FTP directly.
Diagnostic programs and error messages
The server diagnostic programs are stored in upgradable read-only memory (ROM)
on the system board. These programs are the primary method of testing the major
components of the server.
Diagnostic error messages indicate that a problem exists; they are not intended to
be used to identify a failing part. Troubleshooting and servicing of complex
problems that are indicated by error messages should be performed by trained
service personnel.
Sometimes the first error to occur causes additional errors. In this case, the server
displays more than one error message. Always follow the suggested action
instructions for the first error message that appears.
The following sections contain the error codes that might appear in the detailed test
log and summary log when running the diagnostic programs.
The error code format is as follows:
fff-ttt-iii-date-cc-text message
where:
fff is the three-digit function code that indicates the function being
tested when the error occurred. For example, function code 089 is
for the microprocessor.
ttt is the three-digit failure code that indicates the exact test failure that
was encountered.
iii is the three-digit device ID.
date is the date that the diagnostic test was run and the error recorded.
cc is the check digit that is used to verify the validity of the information.
text message is the diagnostic message that indicates the reason for the problem.
Diagnostics 13