Error Code/Symptom FRU/Action
1301
(cable to front panel not found)
1. Cable
2. Front Panel
3. Power Switch Assembly
4. System Board
1302
(cable from system board to power on and
reset switches not found)
1. Cable
2. Power Switch Assembly
3. System Board
1303
(cable from system board to power
backplane not found)
1. Cable
2. Power Backplane
3. System Board
1304
(cable to diagnostic LED board not found)
1. Cable
2. Diagnostic LED Board
3. System Board
1600
(Advanced System Manage-ment
processor is not functioning) Do the
following before replacing a FRU:
1. Ensure that a jumper is not installed
on J5.
2. Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
1. System Board
2. Service Processor Board
1601
(The system is able to communicate to the
Service Processor, but the Service
Processor failed to respond at the start of
POST.)
Do the following before replacing a FRU:
1. Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
2. Flash update the Service Processor.
1. System Board
2. Service Processor Board
1800
(No more hardware interrupt available for
PCI adapter)
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1962
(Drive does not contain a valid boot
sector)
1. Verify a bootable operating system is installed.
2. If RAID system, refer to the Hardware Maintenance Manual for the
specific RAID adapter.
3. Run Diagnostics
4. Hard Disk Drive
5. Cable
6. SCSI Backplane
7. System Board
Symptom-to-FRU index 113