IBM 8682 Server User Manual


 
Error Code/Symptom FRU/Action
201-XXX-0NN
(Failed Memory test, see Memory
Settings on page 37) NN = DIMM
location.
1. DIMM Location J1-J16
2. Memory card
201-XXX-999
(Multiple DIMM failure, see error text.)
1. See error text for failing DIMMs
2. Memory card
202-XXX-001
(Failed System Cache test)
1. Microprocessor CPU 1
202-XXX-002
(Failed System Cache test)
1. Microprocessor CPU 2
202-XXX-003
(Failed System Cache test)
1. Microprocessor CPU 3
202-XXX-004
(Failed System Cache test)
1. Microprocessor CPU 4
206-XXX-000
(Failed Diskette Drive test)
1. Cable
2. Diskette Drive
3. System Board
215-XXX-000
(Failed IDE CD-ROM test)
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
217-XXX-000
(Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed
disk number refers to the RAID logical
array.
1. Fixed Disk 1
217-XXX-001
(Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed
disk number refers to the RAID logical
array.
1. Fixed Disk 2
217-XXX-002
(Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed
disk number refers to the RAID logical
array.
1. Fixed Disk 3
217-XXX-003
(Failed BIOS Fixed Disk test)
Note: If RAID is configured, the fixed
disk number refers to the RAID logical
array.
1. Fixed Disk 4
106 IBM xSeries 350 Type 8682: Hardware Maintenance Manual