IBM 8682 Server User Manual


 
v Size (4 U)
Height: 178 mm (7 in.) (4 U)
Depth: 711.2 mm (28 in.)
Width: 482.6 mm (19 in.)
Weight: 34.9 kg (77 lb.) to 50.4 kg (111 lb.) depending upon configuration
v Integrated functions:
Advanced System Management processor with Light Path Diagnostics
Dual channel Ultra160 SCSI controller (one internal and one external channel)
(non-RAID)
One 10BASE-T/100BASE-TX AMD Ethernet controller
Two serial ports
One parallel port
Two universal serial bus ports
Keyboard port
Mouse port
Video port
v Acoustical noise emissions:
Sound power, idling: 6.3 bel maximum
Sound power, operating: 6.3 bel maximum
Sound pressure, operating: 48 dBa maximum
v Environment:
Air temperature:
- Server on: 10° to 35°C (50° to 95°F). Altitude: 0 to 914 m (3000 ft.)
- Server on: 10° to 32°C (50° to 89.6°F). Altitude: 914 m (3000 ft.) to 2133 m
(7000 ft.)
- Server off: 10° to 43°C (50° to 110°F). Maximum altitude: 2133 m (7000 ft.)
Humidity:
- Server on: 8% to 80%
- Server off: 8% to 80%
v Heat output:
Approximate heat output in British Thermal Units (BTU) per hour
Minimum configuration:461 BTU (0.14 kilowatts per hour)
Maximum configuration: 1796 BTU (0.53 kilowatts per hour)
v Electrical input:
Sine-wave input (50-60 Hz) required
Input voltage low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
Input voltage high range:
- Minimum: 180 V ac
- Maximum: 265 V ac
Input kilovolt-amperes (kVA) approximately:
- Minimum: 0.08 kVA
- Maximum: 0.52 kVA
4 IBM xSeries 350 Type 8682: Hardware Maintenance Manual