158 WLAN Application Gateway 2246
Procedure 22
Setting or changing a password
Step Action
1 From the NetLink OAI System screen, select Change
Password and press Enter.
The Change Password screen displays.
An asterisk (*) indicates an item that is not applicable.
2 Enter the default password:
admin
3 Follow the prompts to configure a new password.
--End--
System status
Use the steps in Procedure 23 “Viewing system status” (page 158) to view
the status of the system.
Procedure 23
Viewing system status
Step Action
1 From the NetLink OAI System screen, select the System
Status Menu option.
2 At the Systems Status Menu screen, select from the following
options:
• Application Active—Yes appears if the application is
communicating correctly with the WLAN Application Gateway
2246. No appears if the application is not connected. This
field is read-only and changes dynamically.
•
Error Status—The only application-specific error is No ECP
heartbeat, which means the application failed to send a
heartbeat to the WLAN Application Gateway 2246.
• Network Status—information about the connection to the
LAN. See “Network status” (page 159).
• Software Versions—lists the software versions currently
running on the WLAN Application Gateway 2246. See
“Software versions” (page 160).
• * Telephone Line Status—provides information about the
functioning of each wireless handset registered to the WLAN
Nortel Communication Server 1000
WLAN IP Telephony Installation and Commissioning
NN43001-504 03.04 Standard
23 September 2008
Copyright © 2004–2008 Nortel Networks
.