Nortel Networks 1000 Switch User Manual


 
200 Troubleshooting WLAN IP Telephony installations
Diagnostics Screen 5 displays the following information:
Sec-ErrCount
nnnnn
LstSecErrSeq
nnnnn
where
Sec-ErrCount is the security error count since power
up.
LstSecErrSeq is the MAC frame sequence number with
the last security error.
Syslog Mode
A Syslog Server must be present on the network so that the handset can
send log messages and have them saved. The Syslog Server IP address
can be configured using DHCP or statically configured.
ATTENTION
If the Syslog Server address is blank (000.000.000.000 or 255.255.255.255) or
the handset is using DHCP and no option 7 is received from the DHCP server,
the handset does not send any syslog messages.
Each syslog message includes the following:
Date and time (to 1100th of a second) since the handset power on
(configured to January 1 00:0:00); requires an SNTP server
WLAN Handset MAC address
WLAN Handset IP address
Sequence number
plus, additional items, based on the message type, as shown in Table
28 "Syslog message contents" (page 201).
Message example:
Jan 1 00:01:26 0090.7a02.2a1b (172.16.0.46) [001a] RStat: AP
00:40:96:48:1D:0C (-56dBm), Sent 783523, Recvd 791342, MSnt 245, MRcd
5674, BSnt 43, BRcd 10783, TX drop 43 (0.0%), TX retry 578 (1.2%), RX retry
1217 (1.6%).
Table 28 "Syslog message contents" (page 201) contains the contents of
the syslog messages.
Nortel Communication Server 1000
WLAN IP Telephony Installation and Commissioning
NN43001-504 03.04 Standard
23 September 2008
Copyright © 2004–2008 Nortel Networks
.