Nortel Networks 1000 Switch User Manual


 
206 Troubleshooting WLAN IP Telephony installations
Table 29
Syslog reason codes (cont’d.)
Reason code
number
Meaning
44
DELTS
45
QOS REQUIRED
46
CHANGED LISTEN INTERVAL
Data capture
Use the information presented in this section to begin capturing the correct
data for analysis.
Questions
Ask the following questions to help isolate the source of a problem:
Is the issue present with handsets that are associated to the same
AP—yes or no?
Is the issue present with handsets that are associated to different APs,
which are associated to same controller—yes or no?
Is the issue present with handsets that are associated to different APs,
which are associated to two different controllers in the same mobility
group—yes or no?
Data checklist
Gather the following data from the site for analysis:
wired ip sniffer trace on the mirrored port for the WLAN IP Telephony
Manager 2245
wireless ip sniffer trace at the AP to which the test handset is
associated
syslog capture
For more information, see “Syslog capture configuration” (page 208).
logs of the event from the Signaling Server
isetShow output from the Signaling Server or from the Voice Gateway
Media Card (VGMC) running as Leader
screenshots of each screen in the WLAN IP Telephony Manager 2245
screenshots of the DHCP server scope with the fields fully expanded
(no truncation of data in the view)
Nortel Communication Server 1000
WLAN IP Telephony Installation and Commissioning
NN43001-504 03.04 Standard
23 September 2008
Copyright © 2004–2008 Nortel Networks
.