C1553M-B (4/05) 117
Figure 144. Edited Access Control Points
Delete an Access Control Point
Click the point that you want to delete, and then click Delete.
To select multiple points, hold the Ctrl key down while clicking each point that you want to delete.
CONFIGURE PATTERN MATCHING FOR INCOMING ALARM STRINGS
Figure 145. Pattern Matching Tab
The Pattern Matching tab is used to configure the pattern(s) that incoming alarm strings must match as the first step in identifying alarms to be
handled by VMX300(-E). If an incoming string matches one of the patterns, VMX300(-E) attempts to match the point number in the string to the
number of a point defined on the Access Control Points tab. If a match is found, VMX300(-E) sets the value of the point’s read property. If no
match is found, VMX300(-E) discards the string.