NetEngine IAD User Guide
Voice Path Configuration 159
Configuring the Ring Test
Type C to configure the ring test.
1. The IAD displays the port prompt:
Port to enable.
Type the port number and press Enter.
2. The IAD displays the on hook timing prompt:
Number of seconds for port to stay on hook.
Type the value in seconds and press Enter.
3. The IAD displays the off hook timing prompt:
Number of seconds for port to stay off hook.
Type the value in seconds and press Enter.
Displaying Ring Test Parameters
Type D to display the current ring test parameters.
The IAD displays the following information:
port = 2, onhooktime = 5, offhooktime = 8S.
Starting and Stopping the Ring Test
Type S to start the ring test.
The IAD displays the menu and begins the ring test on the specified port.
The ring test continues until you stop the test by pressing option T.
Displaying the IAD State
Type S to display the on hook state for each port.
The IAD displays the following information:
Attempting to Connect to CPX, counter = 0
Port 01 is offhook Call Control state = Idle POTS state = Disabled
Port 02 is offhook Call Control state = Idle POTS state = Disabled
Port 03 is offhook Call Control state = Idle POTS state = Disabled
Port 04 is offhook Call Control state = Idle POTS state = Disabled
Port 05 is offhook Call Control state = Idle POTS state = Disabled
Port 06 is offhook Call Control state = Idle POTS state = Disabled
Port 07 is offhook Call Control state = Idle POTS state = Disabled
Port 08 is offhook Call Control state = Idle POTS state = Disabled
Received Segmentation Layer CRC failures since powerup = 0
Configuring Trace Settings
These commands are reserved for use by JetStream or Verilink network
engineers.
Selecting Insufficient Bandwidth Sound
Type V to select the type of dial tone heard by the telephone user if there
is insufficient WAN bandwidth to complete a call. The IAD displays the
Insufficient Bandwidth Indication Setting menu and the current setting: