NetEngine IAD User Guide
WAN Configuration 78
Figure 4–33. Configure S-Bits Menu
3. To toggle a given bit, type the corresponding option number.
4. The IAD saves the configuration and displays the menu.
5. Continue setting S-bits. When you’ve finished, press Escape to return
to the E1 Configuration menu and continue configuration tasks.
6. Reset the IAD (page 15) when you finish E1 configuration.
Configuring the Transmit and Receive Channels
Type 5 to select Configure Transmit Channels, or type 6 to select
Configure Receive Channels.
The IAD displays a message indicating the number of channels enabled,
and displays the Channel Configuration menu.
Figure 4–34. Channel Configuration Menu
For each option, proceed to the corresponding section.
Enabling or Disabling All Channels
1. Type 1 to enable all channels. Type 2 to disable all channels.
2. The IAD makes the change and resets the interface. (The menu and
reset messages may conflict—press any key to refresh the menu.)
*******************************************
Configure S-Bits Menu
*******************************************
Current S-Bit Configuration:
Sa4 Bit = Cleared
Sa5 Bit = Cleared
Sa6 Bit = Cleared
Sa7 Bit = Cleared
Sa8 Bit = Cleared
2. Toggle Sa4 Bit
3. Toggle Sa5 Bit
4. Toggle Sa6 Bit
5. Toggle Sa7 Bit
6. Toggle Sa8 Bit
Tx Channels Enabled = No Channels Enabled.
************************************
Channel Configuration Menu
************************************
* 1. Enable All Channels *
* 2. Disable All Channels *
* 3. Select Individual Channels *
* 4. Select Channel Range *
**
* Esc To Return To Previous menu *
************************************