Polycom 6000 Network Router User Manual


 
NetEngine IAD User Guide
Administration 30
Enabling and Disabling SNMP via IP
Type E to enable or disable SNMP via IP:
1. The IAD displays the current status of SNMP and a prompt:
SNMP via IP is currently DISABLED
To enable SNMP, type E. To disable SNMP, type D.
2. The IAD saves the configuration (if changed). Continue with other
SNMP settings, or press Escape to return to the Main menu.
3. Reset the IAD (page 15) for changes to take effect.
Enabling and Disabling SNMP via EOC
Type F to enable or disable SNMP via EOC:
1. The IAD displays the current status of SNMP and a prompt:
SNMP via EOC is currently DISABLED
To enable SNMP, type E. To disable SNMP, type D.
2. The IAD saves the configuration (if changed). Continue with other
SNMP settings, or press Escape to return to the Main menu.
3. Reset the IAD (page 15) for changes to take effect.
Enabling SNMP via IP and EOC
Type A to enable SNMP via IP and EOC.
The IAD saves the configuration. Continue with other SNMP settings, or
press Escape to return to the Main menu.
Reset the IAD (page 15) for changes to take effect.
Disabling SNMP via IP and EOC
Type B to disable SNMP via IP and EOC.
The IAD saves the configuration. Continue with other SNMP settings, or
press Escape to return to the Main menu.
Reset the IAD (page 15) for changes to take effect.
Configuring the System Contact
Type P to configure system contact (up to 39 alphanumeric characters):
1. The IAD displays the current system contact and prompt:
System Contact is currently: Verilink
Enter new System Contact >
Type the name of the new contact person or department and press
Enter.
2. The IAD save the configuration. Continue with other SNMP settings, or
press Escape to return to the Main menu.
3. Reset the IAD (page 15).