6 – Removal/Replacement
I/O Blades
6-8 59043-06 A
0
3. Open a Telnet session and enter the Hotswap command. You can also
replace an I/O blade using the SANsurfer Switch Manager application.
Perform the tasks as prompted:
SANbox2-64 (admin) #> hotswap
This command will guide you through the hotswap process.
If this process is not followed exactly, then a seamless
transition cannot be guaranteed and a switch power cycle
will be required.
4. Choose the Replace task (1).
The following procedures may be performed:
1) Replace installed IO blade
2) Insert an IO blade
3) Remove an IO blade
4) Exit this process
Which procedure above do you want to initiate?
(1-4): [4] 1
5. Choose the slot number (6 for example).
Which IO blade (indexed by slot number) do you want
to replace? (1,2,3,4,6,7,8,9): [1] 6
6. Disconnect all cables from the selected I/O blade.
Remove all connections from the IO blade in slot 6.
Note: The switch will become unresponsive if you do not perform the tasks
as prompted. If the switch becomes unresponsive, you must power
cycle the switch.
WARNING!!
Voltage is present in an open slot when the switch is operating. To
avoid personal injury or damage to components, do not place
hands or objects into a slot.
AVERTISSEMENT!!
Lorsque le commutateur est en marche, la module est sous
tension. Pour éviter toute blessure personnelle ou dommage aux
composants, ne pas placer les mains ou des objets dans
l’ouverture.
WARNUNG!!
In einem offenen Steckplatz ist Spannung vorhanden, wenn der
Switch in Betrieb ist. Zur Vermeidung von Verletzung oder
Beschädigung von Komponenten weder die Finger noch
irgendwelche Objekte in einen Steckplatz einführen.