4 – Installation
Installing a Switch
59043-06 A 4-21
0
d. About 10 seconds later, the switch is operational: the Input Power LED
remains illuminated, the Heartbeat LED flashes steadily, and the two
remaining LEDs are extinguished. If the Heartbeat LED blinks steadily
about once per second, the POST was successful and you can
continue with the installation process. Any other blink pattern indicates
that an error has occurred. Refer to “Heartbeat LED Blink Patterns” on
page 5-2 for more information about the error blink pattern.
4. Confirm that the Output Power LEDs on both power supplies are illuminated.
If not, check the power cords and the AC voltage source. Refer to “Output
Power LED Is Extinguished” on page 5-12 for more information about
troubleshooting procedures.
The application opens with the Initial Start dialog. Refer to the SANbox2-64 Switch
Management User’s Guide for more information about using, exiting, and
uninstalling SANsurfer Switch Manager.
4.2.8
Configure the Switch
You can configure the switch using the SANsurfer Switch Manager application or
the command line interface. To configure the switch using SANsurfer Switch
Manager, click the Open Configuration Wizard radio button in the Initial Start
dialog, then click the Proceed button. The Configuration wizard explains and
prompts you for the following configuration information:
Temporary IP address
Temporary subnet mask
Archive template file
Switch domain ID (1–-239)
Domain ID Lock (Locked/Unlocked)
Switch name
Permanent IP address
Permanent subnet mask
Permanent gateway address
Permanent network discovery method
Date and time
Admin account password
Create a configuration archive?