Q-Logic QLA2342 Switch User Manual


 
6 – Removal/Replacement
I/O Blades
6-10 59043-06 A
0
9. Slide the I/O blade into the slot guide until it makes contact with the
backplane connector. Rotate the blade latch upward to lock the I/O blade in
place. Fasten the screws. Reconnect the Fiber Channel port cables
according to their labels. After confirming that the I/O blade has been
installed, the Port Status LEDs will flash amber in port number sequence,
then the Port Status LEDs will flash green.
o Insert the replacement IO blade into the chassis in slot 6.
o Attach all connections, if any, to the IO blade in slot 6.
Have the above operations been completed? (y = proceed / n =
cancel) y
10. Verify the POST results. The I/O blade diagnostic status appears in the
dialog. The status should be "Passed".
Hotswap IO blade process successfully completed.
Diagnostics has been run on the IO blade in slot 6: Passed
11. The system checks the I/O blades for matching Zircon processor firmware. If
any of the I/O blades are not compatible, an alarm message will be
generated indicating that a Zircon firmware mismatch has occurred. To
display the alarm messages, enter the Show Alarm command or use the
SANsurfer Switch Manager event browser. Refer to ”Show Command” on
page B-62 for more information. If a mismatch does occur, contact your
authorized maintenance provider.
SANbox2-64 #> show alarm
[9][Wed Jan 16 13:32:19.500 2003]
[A4101][0xdd0072c2.329][IO-1 Zircon firmware mismatch:
rev 0.5, should be perhaps rev 0.7]
Note: A “Failed” status could indicate a faulty blade or module. Enter
the Show POST Log command for more information or contact
your authorized maintenance provider.