Xerox -07W & -11W Printer User Manual


 
8-16
File Transfer
Remote Command
Factory default: Not specified
This enables you to enter a command that will be sent to the remote end to initiate the
file transfer. If a remote command is specified, this will be sent to the host with a
terminating carriage return character before the transfer is started.
Window Size
Factory default: 8192
When a file transfer has been initiated, ZMODEM will send data continuously to the
receiving end. If the receiving end is slower, then data will be stored on the network.
This may cause a problem if an error occurs because the message will take longer to
get through to the sender due to the amount of data still waiting on the network.
This option enables you to overcome the problem by limiting the amount of data that
is stored on the network before waiting for an acknowledgement from the receiver.
The window size relates to the network area taken up by the transfer data. A setting
of 0 (zero) specifies that the window size is unlimited. Any other numeric value
entered here will be rounded to 256 bytes or the nearest multiple of 64 if higher.
Escape Control Codes
Factory default: Unselected
The setting of this option determines whether control codes are sent on their own
(default) or preceded by the escape code CTRL X.
The escape code prevents problems caused by the removal of control codes during
transmission. When this option is selected, control codes are sent as readable
characters preceded by CTRL X.