3Com 7750 Series Switch User Manual


  Open as PDF
of 1177
 
3Com Switch 7750 Series
Command Reference Guide — GVRP Commands Chapter 1
GVRP Configuration Commands
1-4
Timer Lower threshold Upper threshold
Join
This lower threshold is
greater than or equal to twice
the timeout time of the Hold
timer. You can change the
threshold by changing the
timeout time of the Hold
timer.
This upper threshold is less than
one-half of the timeout time of the
Leave timer. You can change the
threshold by changing the timeout
time of the Leave timer.
Leave
This lower threshold is
greater than twice the timeout
time of the Join timer. You
can change the threshold by
changing the timeout time of
the Join timer.
This upper threshold is less than the
timeout time of the LeaveAll timer.
You can change the threshold by
changing the timeout time of the
LeaveAll timer.
LeaveAll
This lower threshold is
greater than the timeout time
of the Leave timer. You can
change threshold by
changing the timeout time of
the Leave timer.
32,765 centiseconds
Related command: display garp timer.
Example
# Set the GARP Join timer to 20 centiseconds for port Ethernet1/0/1.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] interface Ethernet1/0/1
[3Com-Ethernet1/0/1] garp timer join 20
1.1.4 garp timer leaveall
Syntax
garp timer leaveall timer-value
undo garp timer leaveall
View
System view
Parameter
timer-value: Setting (in centiseconds) of the GARP LeaveAll timer. You need to set this
argument with the Leave timer settings of other Ethernet ports as references. That is,
this argument needs to be larger than the Leave timer settings of any Ethernet ports.