3Com 7750 Series Switch User Manual


  Open as PDF
of 1177
 
3Com Switch 7750 Series
Command Reference Guide – Routing Protocol Chapter 5 BGP Configuration Commands
5-54
Parameter
keepalive-interval: Set the interval time value for keepalive time. The range is 1 to
65535. By default, its value is 60 seconds.
holdtime-interval: Set the interval time value for hold time. The range is 3 to 65535. By
default, its value is 180 seconds.
Description
Use the timer command to configure the Keep-alive and Hold-time timer of BGP.
Use undo timer command to restore the default value of the Keep-alive and
Hold-time of the timer.
Example
# Configure the Keep-alive timer as 30 seconds and Hold-time timer as 90 seconds.
<3Com>system-view
System View: return to User View with Ctrl+Z.
[3Com] bgp 100
[3Com-bgp] timer keepalive 120 hold 360
5.1.64 undo synchronization
Syntax
undo synchronization
View
BGP view
Parameter
None
Description
Use the undo synchronization command to cancel the synchronization of BGP and
IGP.
By default, BGP does not synchronize with IGP.
If the local BGP is not set synchronous with the IGP and the next hop of the learned
BGP route is reachable, the local BGP will add this BGP route into its routing table
immediately after it learns the route, rather than waiting till the IGP also learns the
route.
This command means BGP does not synchronize with IGP in current system. You
need not configure it for Switch 7750 Series Ethernet Switches don’t support
synchronization of BGP and IGP at present.