3Com 7750 Series Switch User Manual


  Open as PDF
of 1177
 
3Com Switch 7750 Series
Command Reference Guide – MSTP Chapter 1
MSTP Configuration Commands
1-11
receive configuration BPDUs and then reports these cases to the administrator. If a port
is shut down, only the administrator can restore it.
Example
# Enable the BPDU protection function.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] stp bpdu-protection
1.1.11 stp bridge-diameter
Syntax
stp bridge-diameter bridgenum
undo stp bridge-diameter
View
System view
Parameter
bridgenum: Network diameter to be set for a switched network. This argument ranges
from 2 to 7.
Description
Use the stp bridge-diameter command to set the network diameter of a switched
network. The network diameter of a switched network is represented by the maximum
possible number of switches between any two terminals in a switched network.
Use the undo stp bridge-diameter command to revert to the default network diameter.
By default, the maximum number of switches between any two terminal devices in the
switched network is 7.
After you configure the network diameter of a switched network, MSTP adjusts its Hello
time, Forward delay, and Max age settings accordingly. With the network diameter set
to 7 (the default), the three time-relate settings, Hello time, Forward delay, and Max age,
are set to their defaults as well.
The stp bridge-diameter command only applies to CIST; it is invalid for MSTIs.
Related command: stp timer forward-delay, stp timer hello, and stp timer max-age.
Example
# Set the network diameter to 5.
<3Com> system-view
System View: return to User View with Ctrl+Z.