3Com 7750 Series Switch User Manual


  Open as PDF
of 1177
 
3Com Switch 7750 Series
Command Reference Guide – SNMP & RMON Chapter 2 RMON Configuration Commands
2-10
With an alarm entry defined in an alarm group, a network device performs the following
operations accordingly:
z Sample the defined alarm variables (alarm-variable) once in each specified period,
which is specified by the sampling-time argument.
z Comparing the sampled value with the set threshold and performing the
corresponding operations, as described in
Table 2-7.
Table 2-7 Sample value and the corresponding operation
Comparison Operation
The sample value is larger than or equal to the
set upper threshold (threshold-value1)
Triggering the event identified by
the event-entry1 argument
The sample value is smaller than the set lower
threshold (threshold-value2)
Triggering the event identified by
the event-entry2 argument
Note:
z Before adding an alarm entry, you need to use the rmon event command to define
the events to be referenced by the alarm entry.
z Make sure the node to be monitored exists before executing the rmon alarm
command.
Example
# Add the alarm entry numbered 1 as follows:
z The node to be monitored: 1.3.6.1.2.1.16.1.1.1.4.1
z Sampling interval: 10 seconds
z Upper threshold: 50
z The event-entry1 argument identifies event 1.
z Lower threshold: 5
z The event-entry2 argument identifies event 2
z Owner: user1.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] rmon event 1 log
[3Com] rmon event 2 none
[3Com]rmon alarm 1 1.3.6.1.2.1.16.1.1.1.4.1 10 absolute rising_threshold 50
1 falling_threshold 5 2 owner user1
# Delete the alarm entry numbered 15 from the alarm table.
[3Com] undo rmon alarm 15