ADIC 6-00028-01 Rev A Time Clock User Manual


 
Managing the AMASS File System
4-74 Utility Reference 6-00028-01 Rev A
Example
Step 1. Log in as root.
Step 2. To display tape block size and compression values
for volume six, enter the path, utility, and options
shown in the following example:
The output is illustrated in the following example:
Output Fields Defined
The following fields are generated by this utility:
# su root
# /usr/amass/utils/volprint -a 6
# volprint -a 6
VOL VGR POS FLGS LASTPBN VOLSZ DEAD BLKSZ CMPR ERRS LABEL
6 3 NET I 124 24821 0 512 On 0 Pics
Field Description
Volume Number Unique volume number
Volume Group Volume group assignment
Position The home storage slot number
Valid values are:
An alphanumeric value
n/a is valid for standalone drives
NET is valid for network-attached drives