Avaya 1.3 Computer Accessories User Manual


 
DEFINITY ONE Pre-Administration — Setting Up Your Avaya CT Configuration
Issue 1 October 2003 245
8. Type change node-names
The NODE NAMES screen appears.
9. Follow steps a and b to complete the NODE NAMES screen and define the Avaya CT
server’s name and address.
a. In the Name: field, type the name you want to assign to the Avaya CT server (free-
form field)
b. In the IP Address: field, type the IP address of the G3PBX Driver (default is
192.128.25.20)
10. Type add data-module modname (substitute modname with the name of your data
module. For example modul02).
The DATA MODULE screen appears.
11. Follow steps a through e to complete the DATA MODULE screen.
a. In the Data Extension: field, type any valid extension on the dial plan (for
example, 20000).
b. In the Type: field, type ethernet
c. In the Port: field, type 01A1017, where:
01A10 is for the C-LAN board slot (in this example)
017 is the port (must always be port 17)
d. In the Link: field, type any number from 1 to 25
e. In the Name: field, type the name you want to assign to the Avaya CT server (free-
form field)