Avaya P550R Switch User Manual


 
Cajun P550/P880/P882 Switch User Guide
Monitoring the Cajun Switch
17-15
4. Refer to Table17-7 for an explanation of the items listed in
the Class column on the General Event Management dialog
box:
5. Click APPLY to save your changes, or CANCEL to restore
previous settings.
Table 17-7. Class Column Items
Class Determines whether or not the switch
sends a notification...
Start Upon system start.
System For system events.
Configuration For each configuration change (for example,
enabling and disabling ports).
Temperature Status Of temperature status changes. Temperature
status message could precede a switch
shutdown, and are often critical.
Resource Upon a change in system resources.
Fan Status Of fan status. Fan failures will eventually lead to
overheating the system. Fan Status message
provide a good early warning for a failure that
could eventually cause the switch to shut down.
Service Port Status/
User Port Status
Of Port status changes for service and user ports.
Set a port as either service port/user port from
the port configuration page. The purpose of this
feature is to allow you to use different
notification level for critical (service ports), if
desired.
Authentication
Failure
When the switch detects an authentication
failure. This is a security-related feature used to
detect unauthorized SNMP activity.
Bridge Status Of changes in bridge status.
Switch Fabric Of failures in the switch fabric. These are critical
failures and should be monitored closely.
OSPF For OSPF events if OSPF protocol event logging
is enabled.
RIP For RIP events if RIP protocol event logging is
enabled.
LDAP For LDAP events if LDAP protocol event logging
is enabled.
AppleTalk For AppleTalk events if AppleTalk protocol event
logging is enabled.