Multiserver 5000
236
INTEGRAL DEVICE NOT Info You have attempted to select an Integral Device
YET DEFINED Menu in which the device has been detected by the
software, but is not yet identified.
Example: A cold start occurs and the user
attempts to access the ISU menu tree
under diagnostics within the first ten
seconds after the reset. Usually a
second attempt will succeed.
INTEGRAL DEVICE Info You have attempted to execute a device
OPTION DISABLED feature or option, but the device is currently
disabled.
INTEGRAL DEVICE Info You have attempted to execute a device feature
OPTION NOT SUPPORTED or option that is not supported by the device under
its current configuration.
INTEGRAL DEVICE TYPE Info The device type in the port selected does
NOT APPLICABLE not apply to the selected menu.
Example: Attempting to configure a port in the
Integral Devices Menu when the port
holds a 56K ISU module. (There are no
configuration menus for the ISU.)
INVALID NAME Info The selected text contains a character(s) or
CHARACTER/S embedded spaces which are not allowed.
Example: Selecting a node name that begins with
a number or contains embedded
spaces.
INVALID PASSWORD Info The password entered does not match the
configured password.
ni/ml LAN MODULE DOWN Info The LAN module in ml is not available for use.
ni/ml LAN MODULE UP Info The LAN module in ml is operating and available.
LEASED CONNECTION Event or Alarm The ADB option has completed the lease line
MADE LINK ci connection for link (ci).
LINK DOWN ci Event or Alarm The local Multiserver has timed out (30 seconds)
waiting for sync to be acquired on link ci. Check the
cabling, modem, and remote Multiserver or feeder
mux for errors.
LINK RESTORED ci Event or Alarm Link ci has been restored and is in sync.
LCD Messages
Message Message Type Explanation