3-52 Diagnostic Tools
DAAD Diagnostic Messages
continued
Message Description Recommended Action
Configuration
signature is
zero
DAAD detected that nonvolatile
RAM contains a configuration
signature that is zero. Old versions
of the System Configuration Utility
could cause this.
Run the latest version of System
Configuration Utility to configure the
controller and nonvolatile RAM.
Configuration
signature
mismatch
Array accelerator board configured
for a different array controller
board. Configuration signature on
array accelerator board does not
match the one stored on the array
controller board.
To recognize the array accelerator board,
run the System Configuration Utility.
Controller
communication
failure
occurred
Controller communication
failure occurred.
DAAD was unable to successfully issue
commands to the controller in this slot.
Controller
detected.
NVRAM
configuration
not present
EISA nonvolatile RAM does not
contain a configuration for this
controller.
Run the System Configuration Utility to
configure the nonvolatile RAM.
Controller
firmware
needs
upgrading
Controller firmware is below the
latest recommended version.
Run Options ROMPaq to upgrade the
controller to the latest firmware revision.
Controller
firmware
needs
upgrading
(DAAD Error
102)
Controller is correct, however, IDA
firmware version should be greater
than 1.26.
Obtain the latest firmware.
Controller is
located in
special “video”
slot
Controller is installed in slot for
special video control signals. If
controller is used in this slot, LED
indicators on front panel may not
function properly.
Install the controller in a different slot and
run the System Configuration Utility to
configure the controller and nonvolatile
RAM.
Controller is
not configured
Controller is not configured. If
controller was previously
configured and you change drive
locations, there may be a problem
with placement of the drives.
DAAD examines each physical
drive and looks for drives that have
Look for messages indicating which drives
have been moved. If none appear and drive
swapping did not occur, run the System
Configuration Utility to configure the
controller and nonvolatile RAM.
Do not
run
the System Configuration Utility if you
believe drive swapping