Compaq 1850R Server User Manual


 
3-17
Compaq ProLiant 1850R Servers Maintenance and Service Guide
1767-Slot x Drive Array Option ROM is Not Programmed
Correctly or may Conflict with the Memory Address Range of an
ISA Card. Check the Memory Address Configuration of installed
ISA Card(s) or run Options ROMPaq Utility to attempt SMART-
2/E Option ROM Reprogramming.
Remove or reconfigure
conflicting ISA cards, especially
any cards that are not
recognized by the System
Configuration Utility. Try
reprogramming the
SMART-2/E Controller’s ROMs
using the latest Options
ROMPaq (version 2.29 or
higher).
1768-Slot x Drive
Array -Resuming
logical drive
expansion
process.
None SMART-2 Controller error No action required. Appears
whenever a controller reset or
power cycle occurs while array
expansion is in progress.
continued