Compaq 1850R Server User Manual


 
3-12 Diagnostic Tools
POST Error Messages
continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
703-CMOS
reports a
coprocessor that
has not been
detected
2S Coprocessor or
configuration error.
1. Run the System
Configuration Utility and
correct.
2. Replace the coprocessor.
1151-Com Port 1
Address
Assignment
Conflict
2S Both external and internal
serial ports are assigned
to COM1.
Run the System Configuration
Utility
and correct.
1152-Com Port
2, 3, or 4
Address
Assignment
Conflict
2S Both external and internal
serial ports are assigned
to COM2, COM3 or
COM4.
Run the System Configuration
Utility
and correct.
1600-Server
Manager/R
Failure
None Server Manager/R board
failure. Error code displays
after error message.
Run Diagnostics. Replace failed
assembly as indicated.
1610-
Temperature
violation
detected.
Waiting for
system
to cool
2S Ambient system
temperature too hot.
Check fan in system
environment.
1611-Fan [fan
description]
failure detected
2S Required fan has failed. Check fans.
1611- Fan [fan
description] not
present
2S Fan not present. Make sure fans are plugged in.
1612-Primary
power supply
failure
2S Primary power supply
has failed.
Replace power supply as soon
as possible.
1613-Low
System Battery
None Real time clock system
battery is running low on
power.
Run Diagnostics. Replace failed
assembly as indicated.