Compaq 1850R Server User Manual


 
3-58 Diagnostic Tools
DAAD Diagnostic Messages
continued
Message Description Recommended Action
Drive (bay) X
was
inadvertently
replaced
The physical drive was
incorrectly replaced after another
drive failed.
Replace the drive that was incorrectly
replaced and replace the original drive that
failed. Do not run the System Configuration
Utility and try to reconfigure;
data will be lost.
Duplicate write
memory error
Data could not be written to the
array accelerator board in
duplicate due to the detection of
parity errors. This is not a data
loss situation.
Replace the array accelerator board.
Error occurred
reading RIS
copy from
drive (bay) X
An error occurred while DAAD
was trying to read the RIS from
this drive.
If there were multiple errors, this drive may
need to
be replaced.
FYI: Drive
(bay) X is non-
Compaq
supplied
The installed drive was not
supplied by Compaq.
If problems exist with this drive, replace it with
a
Compaq drive.
Identify
controller data
did not match
with NVRAM
The identify controller data from
the array controller did not
match with the information
stored in nonvolatile RAM. This
could occur if new, previously
configured drives have been
placed in a system that has also
been previously configured. It
could also occur if the firmware
on the controller has been
upgraded and the System
Configuration Utility was not run.
Check the identify controller data under the
Inspect Utility. If the firmware version field is
the only thing different between the controller
and nonvolatile RAM data, this is not a
problem. Otherwise, run the System
Configuration Utility.
Identify logical
drive data did
not match with
NVRAM
The identify unit data from the
array controller did not match
with the information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has also
been previously configured.
Run the System Configuration Utility to
configure the controller and nonvolatile RAM.
Insufficient
adapter
resources
The adapter does not have
sufficient resources to perform
operations to the array
accelerator board. Drive rebuild
Operate the system without the array
accelerator board until the drive rebuild
completes.