Compaq 1850R Server User Manual


 
3-23
Compaq ProLiant 1850R Servers Maintenance and Service Guide
POST Error Messages
continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1789-Drive Not
Responding,
Physical Drive
Check cables or
replace physical
drive
X
.
Select "F1" to
continue - drive
array will remain
disabled.
Select "F2" to fail
drive(s) that are
not responding -
Interim Recovery
Mode will be
enabled if
configured for
fault tolerance.
None Cable or hard drive
failure.
1. Check the cable connections.
2. If cables are connected,
replace the drive.
3. If you do not want to replace
the drives now, press
F2
.
1790-Disk 0
Configuration
Error
None Hard drive error or
wrong
drive type
Run the System Configuration
Utility and Diagnostics and
correct.
1791-Disk 1
Error
None Hard drive error or
wrong
drive type.
Run the System Configuration
Utility and Diagnostics and
correct.
1792-Drive Array
Reports Valid
Data Found in
Array
Accelerator.
Data will
automatically be
written to drive
array.
None This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory. Power was
then restored within
eight to ten days, and
the data in the Array
Accelerator was flushed
to the drive array.
No action necessary; no data has
been lost. Perform orderly system
shutdowns to avoid data
remaining in the Array
Accelerator.
continued