Compaq 1850R Server User Manual


 
3-14 Diagnostic Tools
POST Error Messages
continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1702-SCSI cable
error detected.
System halted.
None Incorrect cabling. 1. For integrated SCSI
Controllers, ensure that the
internal connector has SCSI
termination attached.
2. For option card SCSI
controllers, ensure that only
one of the
two internal connectors has
termination attached.
1703-SCSI cable
error detected.
Internal SCSI
cable not
attached to
system board
connector.
System halted.
None Incorrect cabling. Ensure that the integrated SCSI
controller has SCSI termination
attached.
1704-
Unsupported
Virtual Mode
Disk Operation.
DOS Driver
Required.
System halted.
None System attempted to
perform a virtual mode
disk operation without
virtual mode
memory services.
Use fixed-disk device driver that
supports virtual mode memory
services.
1705-Locked
SCSI Bus
Detected.
System halted.
None SCSI bus failure. Run Diagnostics. Replace failed
assembly as indicated.
1730-Fixed Disk
0 does not
support DMA
Mode.
None Fixed disk drive error. Run the System Configuration
Utility and correct.
1731-Fixed Disk
1 does not
support DMA
Mode.
None Fixed disk drive error. Run the System Configuration
Utility and correct.
1740-Fixed Disk
0 failed Set Block
Mode command
None Fixed disk drive error. Run the System Configuration
Utility and correct.