3-81
Compaq ProLiant 1850R Servers Maintenance and Service Guide
Critical Error Log
The Critical Error Log records memory errors, as well as catastrophic hardware and software
errors that cause the system to fail. This information helps you quickly identify and correct the
problem, thus minimizing downtime.
You can view the Critical Error Log through the Compaq Insight Manager. The Diagnostics
Utility either resolves the error or suggests corrective action in systems that do not support
event logs.
The Critical Error Log identifies and records all the following errors. Each error type is briefly
explained below.
Table 3-24
Critical Error Log Messages
Message Description
Abnormal Program
Termination
The operating system has encountered an abnormal situation that has
caused a
system failure.
ASR-2 detected by
ROM
An ASR-2 activity has been detected and logged by the system ROM.
ASR-2 Test Event The System Configuration Utility generated a test alert.
Automatic Server
Recovery Base Memory
Parity Error
The system detected a data error in base memory following a reset due to
the Automatic Server Recovery-2 (ASR-2) timer expiration.
Automatic Server
Recovery Extended
Memory Parity Error
The system detected a data error in extended memory following a reset
due to the ASR-2 timer expiration.
Automatic Server
Recovery Memory
Parity Error
The system ROM was unable to allocate enough memory to create a
stack. Then, it was unable to put a message on the screen or continue
booting the server.
Automatic Server
Recovery Reset Limit
Reached
The maximum number of system resets due to ASR-2 timer expiration has
been reached, resulting in the loading of Compaq Utilities.
Battery Failing Low system battery warning. Replace battery within 7 days to prevent loss
of nonvolatile configuration memory. Failure of the battery supporting the
system’s nonvolatile RAM
is imminent.
Caution: Temperature
Exceeded
The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
Diagnostic Error An error was detected by the Diagnostics Utility. See the specific error
code in this chapter for a detailed explanation.