Compaq 1850R Server User Manual


 
3-24 Diagnostic Tools
POST Error Messages
continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1793-Drive Array
- Array
Accelerator
Battery Depleted
- Data Lost
(Error message
1794 also
displays.)
None This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory. Array
Accelerator batteries
failed. Data in Array
Accelerator has been lost.
Power was not restored within
eight to ten days. Perform
orderly system shutdowns to
avoid data remaining in the
Array Accelerator.
1794-Drive Array
- Array
Accelerator
Battery Charge
Low. Array
Accelerator is
temporarily
disabled. Array
Accelerator will
be re-enabled
when battery
reaches full
charge.
None This is a warning that the
battery charge is below
75%. Posted-writes are
disabled.
Replace the Array Accelerator
board if batteries do not
recharge within 36 power-on
hours.
1795-Drive Array
- Array
Accelerator
Configuration
Error.
Data does not
correspond to
this drive array.
Array
Accelerator is
temporarily
disabled.
None This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory.
The data stored in the
Array Accelerator does not
correspond to this drive
array.
Match the Array Accelerator to
the correct drive array, or run
the System Configuration Utility
to clear the data in the Array